Abstract:Effects of different ultrasonic irradiation powers (0 W, 100 W, 200 W, 300 W, 400 W) and different ultrasonic irradiation time (0 min, 5 min, 10 min, 15 min) on high-density polyethylene (HDPE) were studied by using the self-designed ultrasonic irradiation equipment. According to the analysis of synchronous thermal analyzer (TGA), the higher the irradiation power is, the longer the irradiation time is, the better the thermal stability of HDPE is. The 5% mass loss temperature of HDPE at 400 W for 15 min is higher than that of non-irradiated HDPE. The 5% mass loss temperature is increased by nearly 26%. XRD and DSC analysis show that the ultrasonic irradiation has the effect of refining crystal grains, irradiation power and irradiation time have effect on the crystallinity of HDPE which reaches the maximum when the power is 200 W for 5 min. The shear viscosity of HDPE treated by the ultrasonic rheometer is reduced by the rotary rheometer. Under the ultrasonic power of 400 W and the irradiation time of 10 min, the shear viscosity is the lowest, which is favorable for processing.