Abstract:The stitched/unstitched foam core material was prepared by VARTM technology, and the impact test and the post-impact compression test were carried out under four different impact energies, respectively. The invisible damage inside the fiber panel was detected by ultrasonic c detection technology. The addition of the columns can effectively improve the impact resistance of the composite structure, wherein the maximum load impact is increased by 20%~50% because with the addition of column, more matrix cracking occurs inside, but the delamination damage and fiber breakage are reduced. And the residual compression strength after impact is also increased by 35%~40%. In addition, it is found that compared with a stitching density of 15 mm×15mm, a stitching density of 10 mm×10 mm has a better impact resistance.