Abstract:Three-dimensional (3-d) simulation technology, an anisotropic rotary diffusion-reduced strain closure (ARD-RSC) model, and a temperature measuring system equipped with integrated thermocouple sensors, and visual holographic tracer technique were used. On this basis, the fibre orientation and deviations of the temperature and flow velocity distributions of glass fibre reinforced polypropylene (GFRPP) melts in the runners during multi-cavity micro-injection moulding were simulated and analyzed. The results show that at a low injection rate, GFRPP melts present a significant fibre orientation; the degree of fibre orientation in the surface area is greater than that in the core of the runners, forming an asymmetric surface-core-surface structure. The fibre orientation aggravates the downward deviation of the temperature and flow velocity distributions of the GFRPP melt flow fronts. At a high injection rate, an asymmetric surface-core-surface structure persists due to the fibre orientation; however, the structure is less significant than that formed at a low injection rate. The effects of the fibre orientation on the downward deviation amplitude of the high-temperature zone and flow velocity distribution of the melt flow fronts are greater than that at a low injection rate. This means that the changes of the flow velocity, flow state, and temperature of GFRPP melts interact at different injection rates, which causes the fibre orientation of the melts to appear and their flow velocity and temperature distributions to deviate. As a result, it leads to unbalanced filling in the runner system and cavities.