Abstract:In order to reduce the inflammatory response caused by the implantation of nerve electrodes into body, a nano-microstructure composite electrode was constructed. Firstly, multi-walled carbon nanotubes (MWCNTs) and dexamethasone sodium phosphate (Dex) were mixed and dropped onto the electrode after ultrasonic mixing, and then polypyrrole/sodium polystyrene sulfonate(PPy/PSS) was deposited on the electrode surface covered with MWCNTs by electrochemical polymerization, to obtain a functional conductive biofilm MWCNTs/Dex@PPy/PSS. FESEM and FT-IR were used to characterize the morphology and composition of conductive biofilms, and the electrochemical properties of the modified electrodes were analyzed by cyclic voltammetry(CV) and impedance scanning (EIS). The results show that compared with the PPy/Dex conductive biofilm, the prepared MWCNTs/Dex@PPy/PSS conductive biofilm shows a three-dimensional structure surface morphology, higher charge storage capacity, lower impedance, and higher drug release ability.