Abstract:In order to explore the difference between the filling imbalance in micro-scale and traditional injection molding, the key factors affecting the filling imbalance in micro-scale include scale effect, wall slip and convective heat transfer. The numerical simulation experiment of filling flow in H-shaped semi-circular cross section microchannel system with symmetrical distribution was carried out by using polyoxymethylene (POM). By analyzing the temperature difference between the symmetrical points at the gate, the experimental results show that the wall slip can effectively reduce the temperature difference between the symmetrical points and improve the imbalance of filling. Convective heat transfer makes part of the heat of the melt in the flow passage dissipate through the mold, aggravating the imbalance of filling, and the smaller the convective heat transfer coefficient, the more obvious the imbalance of filling. With the decrease of the flow channel size, the wall slip becomes more obvious, and the convective heat transfer reduces the temperature difference between the symmetrical points, which is beneficial to improve the filling imbalance.