硅烷偶联剂对聚四氟乙烯/玻纤复合材料性能的影响
DOI:
作者:
作者单位:

1.中国石油大学(华东) 重质油国家重点实验室,山东 青岛 266580;2.清华大学 高端装备界面科学与技术全国重点实验室,北京 100084

作者简介:

通讯作者:

中图分类号:

基金项目:

高端装备界面科学与技术全国重点实验室自主研究课题(SKLT2025Z04)


Effect of Silane Coupling Agent on the Properties of PTFE/Glass Fiber Composites
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为改善聚四氟乙烯(PTFE)在密封应用中机械性能不足与耐磨性差的问题,分别采用N-(2-氨乙基)-3-氨丙基甲基二甲氧基硅烷(KBM602)、3-氨丙基三乙氧基硅烷(KH550)和3-(甲基丙烯酰氧)丙基三甲氧基硅烷(KH570)三种硅烷偶联剂对玻璃纤维(GF)进行表面改性,并通过冷压烧结工艺制备PTFE/GF复合材料。基于三因素三水平正交实验,系统研究了GF填充量(15 wt%、20 wt%、25 wt%)、偶联剂类型及偶联剂含量(1 wt%、2 wt%、4 wt%)对复合材料力学性能和摩擦磨损性能的影响。傅里叶变换红外光谱(FTIR)证实三种偶联剂均成功接枝于GF表面;断面与磨损表面形貌分析表明,偶联剂处理增强了PTFE基体与GF的界面结合,使压缩性能明显改善。当GF填充量为25 wt%、采用1 wt% KH550改性时,复合材料综合性能最优,压缩模量和压缩强度较未改性体系分别提高32.6%和4.6%;但改性体系的体积磨损率较未改性体系小幅上升,其中1 wt% KH550改性时负面影响最小,磨损机制以磨粒磨损为主并伴随疲劳磨损特征。

    Abstract:

    To address the inadequate mechanical properties and wear resistance of polytetrafluoroethylene (PTFE) in sealing applications, glass fibers (GF) were surface-modified with three silane coupling agents (KBM602, KH550 and KH570), and PTFE/GF composites were fabricated via cold-press sintering. Based on a three-factor, three-level orthogonal design, the effects of GF content (15, 20, 25 wt%), coupling agent type and coupling agent content (1, 2, 4 wt%) on the mechanical and tribological properties were systematically investigated. FTIR results confirmed that all three coupling agents were successfully grafted onto the GF surface. Fracture and worn surface morphology analyses showed that silane treatment enhanced the interfacial bonding between the PTFE matrix and GF, thereby markedly improving the compressive properties. The composite with 25 wt% GF and 1 wt% KH550 exhibited the best overall performance, with compressive modulus and compressive strength increased by 32.6% and 4.6%, respectively, compared with the unmodified system. However, the volume wear rate of the modified composites was slightly higher than that of the unmodified system, and this detrimental effect was minimized at 1 wt% KH550. The wear mechanism of the modified composites was dominated by abrasive wear, accompanied by fatigue wear features.

    参考文献
    相似文献
    引证文献
引用本文
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-10-10
  • 录用日期:2026-05-28
  • 网络出版日期:2026-11-02
  • 在线发布日期:
  • 出版日期:
您是第      位访问者
编辑出版 :《高分子材料科学与工程》编辑部
地址 :四川省成都市一环路南一段24号 四川大学高分子研究所
电话 :028-8540 1653  E-mail:gfzclbjb@vip.sina.com
高分子材料科学与工程 ® 2026 版权所有
技术支持:北京勤云科技发展有限公司