Abstract:Four different thicknesses of composite patches were used to conduct ultrasonic repair experiments on carbon fiber-reinforced thermosetting composites (CFRP) with 10 mm crack damage. A thermoplastic thin film was placed between the repaired sample and the patch, with a thickness of 0.2 mm of polyether ether ketone (PEEK) resin. The results show that the thickness of the patch has a significant impact on the mechanical properties and failure modes of the repaired specimens. As the thickness of the patch increases, the mechanical properties of the repaired specimens show a trend of first increasing and then decreasing. Thicker patches will reduce the mechanical properties and forming effect of the repaired specimens. Among them, when the thickness of the patch is 2.627 mm, the maximum tensile strength can reach 392.7 MPa, and the strength recovery rate can reach 77.8%; when the thickness of the patch is 2.660 mm, the ultimate bearing capacity of the test piece is decreased by 1200.2 N, the tensile strength decreases to 370.5 MPa, and the maximum deformation of the repaired sample is as high as 0.056 mm. Through scanning electron microscopy analysis of the failure mode of the repaired specimens, it is found that the failure mechanism varies with the thickness of the patch. For the test piece with a patch thickness of 0.627 mm, the main failure mode is interface fracture.