Abstract:When the medical thin-wall tube was coated in actual production, the coating layer was required to be thin-wall, which made the cross-section gap area of the straight section flow channel formed by the internal plug and the die small, resulting in excessive pressure of the polymer melt at the shaping section, high die pressure and material melt reflux, all of which directly affected the forming quality of the coating layer. To solve the above problems, the non-isothermal numerical simulation of the coating model with and without the shaping section was conducted by Polyflow. Firstly, the velocity field and pressure field of the two models were analyzed to explore the influence of the non- setting section on the die swell. Subsequently, the impact of the coating model without shaping section on the size of the coating layer and the stability of the coating flow field at varying drag speeds of the wire,inlet flow rates and die temperatures were analyzed, and the coating extrusion process was compared with that of the flow channel with the shaping section. The results indicate that, with the variation of process parameters, the correlated variation patterns of the coating layer dimensions and the uniformity of the coating extrusion flow field are fundamentally consistent between the two models. Die swell cannot be eliminated by setting of the shaping section. In comparison to the conventional coating extrusion, the die pressure drop and energy consumption can be decreased and the coating quality can be enhanced by the coating extrusion without shaping section.